5-30
5-8 Selecting the Reverse Rotation-prohibit
Thisparameterisusedtospecifywhether toenable or disable the reverse
rotation command sent to the Inverter from the control circuit terminals or
Digital Operator.
Theparametershouldbesettonotacceptwhenthe Inverterisappliedto
systems that prohibit the reverse rotation of the Inverter.
H Selecting the Reverse Rotation-prohibit (n006)
n006 Reverse Rotation-prohibit
Selection
Register 0106
Hex
Changes during
operation
No
Setting
range
0, 1 Unit of
setting
1 Default setting 0
Set Values
Value Description
0 Accept
1 Not accept