5-10 Multi-function I/O
5-10-1 Multi-function Input
The3G3MVincorporatessevenmulti-functioninputterminals(S1through
S7).Inputsintotheseterminalshaveavarietyoffunctionsaccordingtothe
application.
H Multi-function digital Input (n050 through n056)
n050 Multi-function digital Input 1 (S1) Register 0132
Hex
Changes during
operation
No
Setting
range
1 to 25 (for 26, see note) Unit of
setting
1 Default setting 1
n051 Multi-function digital Input 2 (S2) Register 0133
Hex
Changes during
operation
No
Setting
range
1 to 25 (for 26, see note) Unit of
setting
1 Default setting 2
n052 Multi-function digital Input 3 (S3) Register 0134
Hex
Changes during
operation
No
Setting
range
0 to 25 (for 26, see note) Unit of
setting
1 Default setting 3
n053 Multi-function digital Input 4 (S4) Register 0135
Hex
Changes during
operation
No
Setting
range
1 to 25 (for 26, see note) Unit of
setting
1 Default setting 5
n054 Multi-function digital Input 5 (S5) Register 0136
Hex
Changes during
operation
No
Setting
range
1 to 25 (for 26, see note) Unit of
setting
1 Default setting 6
n055 Multi-function digital Input 6 (S6) Register 0137
Hex
Changes during
operation
No
Setting
range
1 to 25 (for 26, see note) Unit of
setting
1 Default setting 7
n056 Multi-function digital Input 7 (S7) Register 0138
Hex
Changes during
operation
No
Setting
range
1 to 25, 34, and 35
(for 26, see note)
Unit of
setting
1 Default setting 10
Note Set value 26 is available for 5.5kW and 7.5kW Inverters only.