3-10
3-2 Parameter Copy and Verify Function
The Digital Operator of the 3G3MV Inverter has an EEPROM in which the
setvaluesinalltheparametersanddataon thecapacityandsoftware ver-
sion of the Inverter can be stored.
By using the EEPROM, most parameter set values in the Inverter can be
copied to another Inverter.
Note In the above case, however, the Inverters must have the same power supply
specification and control mode (i.e., V/f or vector control mode). Some types of
parameter set values cannot be copied.
3-2-1 Parameter for Copying and Verifying Set Values
·Use the following parameter to read, copy, and verify the set values.
Parame-
ter
Register Name Description Setting
range
Unit of
setting
Default
setting
Chan-
ges dur-
ing
opera-
tion
n176 01B0 Parame-
ter copy
and
verify
function
selection
The following items are
selectable.
rdy: Ready to accept the
next command
rEd: Reads the parameter
CPy: Copies the parameter
vFy: Verifies the parameter
vA: Displays the capacity of
the Inverter
Sno: Displays the software
version.
rdy to
Sno
--- rdy OK
Note No value can be copied or written while the Inverter is in operation.