5-33
Set Values
Value Function Description
0 Forward/Reverse
rotation command
3-wire sequence (to be set in n052 only)
By setting n052 to 0, the set values in n050 and n051
are ignored and the following settings are forcibly
made.
S1: RUN input (RUN when ON)
S2: STOP input (STOP when OFF)
S3: Forward/Reverse rotation command
(OFF: Forward; ON: Reverse)
1 Forward/Stop Forward rotation command in 2-wire sequence
2 Reverse/Stop Reverse rotation command (2-wire sequence)
3 External fault (NO)
ON: External fault (EFj detection: j is a terminal
number)
4 External fault (NC)
OFF: External fault (EFj detection: j is a terminal
number)
5 Fault reset ON: Fault reset (disabled while RUN command is input)
6 Multi-step speed
reference 1
Signals to select frequency references 2 through 16.
as turned-OFF input.
10 Inching frequency
command
ON: Inching frequency command (taking preference
over the multi-step speed reference)
11 Acceleration/Decel-
eration time selection
ON: Acceleration time 2 and deceleration time 2 are
selected.
12 External base block
command (NO)
ON: Output turned OFF (while motor coasting to a stop
and “bb” flashing)
13 External base block
command (NC)
OFF: Output turned OFF (with motor free running and
“bb” flashing)
14 Search command
(Searching starts
from maximum
frequency)
ON: Speed search (Searching starts from n011)
15 Search command
(Searching starts
from preset
frequency)
ON: Speed search
Basic Operation Chapter 5