EasyManua.ls Logo

Omron SYSDRIVE 3G3MV - Page 135

Omron SYSDRIVE 3G3MV
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-36
S1: RUN input (RUN when ON)
S2: STOP input (STOP when OFF)
S3: Forward/Reverse rotation command (OFF: Forward; ON: Reverse)
·The following diagram shows a wiring example of the terminals in 3-wire sequence.
Stop
switch
(NC)
RUN
switch
(NO)
Direction switch
RUN input (Operates with the RUN switch closed)
Stop input (Stops with the stop switch opened)
Forward/Reverse rotation command (forward with
the direction switched opened)
Sequence input common
H External Base Block Command (Set Value: 12, 13)
WhenanSPST-NO(setvalue:12)orSPST-NC(setvalue:13)inputisreceived,Inverter
outputs are shut OFF. Use these inputs in the following cases to stop Inverter outputs.
· For switching the motor to free running status when applying an external brake.
· For stopping Inverter outputs before disconnecting motor wiring when changing the
motor from an Inverter to a commercial power supply.
Note TheexternalbaseblockonlyshutsOfftheInvertersoutputfrequency,andtheInverters
internal frequency continues to be calculated as usual. Therefore, if the external base
blockisclearedwhenthefrequencyisnotzero,thefrequencycalculatedatthatpointwill
beoutput.Becauseofthis,ifthebaseblockisclearedduringdecelerationwhilethemotor
is free running, a large discrepancy between the motor speed at that moment and the
Inverter output frequency may result in a main circuit overvoltage (OV) or overcurrent
(OC).
Basic Operation Chapter 5

Table of Contents

Other manuals for Omron SYSDRIVE 3G3MV

Related product manuals