EasyManua.ls Logo

Omron SYSDRIVE 3G3MV - Page 182

Omron SYSDRIVE 3G3MV
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-40
Note If set to vector control mode, the default value will be 0.2.
Set Values
·Thisparameterisusedfortheresponseadjustmentof theslipcompensationfunction.
·The default setting does not need any changes in normal operation.
·Change the default setting in the following cases.
The motor vibrates: Set the value to a larger value.
The motor response is low: Set the value to a smaller value.
n113 Slip Compensation During
Regeneration
Register 0171
Hex
Changes during
operation
No
Setting
range
0, 1 Unit of
setting
1 Default setting 0
Set Values
Value Description
0 Slip compensation function disabled during regeneration
1 Slip compensation function enabled during regeneration
·Select whether the slip compensation function is enabled or not, even during regen-
eration (i.e.: when regeneration energy is returning during deceleration, etc.).
·This parameter is only enabled in vector control mode. (In V/f control mode, the slip
compensation function will be disabled during regeneration, regardless of the setting
for this parameter.)
Advanced Operation Chapter 6