7-9
Setting Name Description
18 Communication/control circuit
terminal selection
(Comm/Terminal change over)
Run command from communication -
from serial comm. card if it is
connected
1
), otherwise MEMOBUS
comm. - and frequency reference
(n004= 0 to 8) are effective if
multi-function inout terminal for this
setting is “1” (register no. 0001H,
0002H).
Run command in LOCAL/REMOTE
mode (n003=0,1) and frequency
reference (n004=0 to 8) are effective
if “0”.
1
) new from s/w 010024
26 Inverter overheating pre-alarm OH3 “OH3” is displayed (blinking) on the
digital operator by signal input.
27 Accel/Decel time select 2 2 Multi-func. inputs (two from n050 to
n056) are to set as “11” (Accel./Decel
time select 1) and “27” to switch
among 4 accel./decel. times. (n019 to
n022; n041 to n044)
Communications Chapter 7