7-32
Error
code
RemedyProbable causeName
22 Hex Write mode error
The Inverter in operation received a DSR
message to write data to a parameter
that prohibits any data to be written while
the Inverter is running.
Write the data
after stopping the
Inverter.
The Enter command was received while
the Inverter is running.
The Inverter detecting UV received a
DSR message to write data.
Write the data
after restoring
the UV (main
The Inverter detecting UV received the
Enter command.
circuit
undervoltage)
status.
The Inverter detecting F04 for an
initialization memory fault received a
DSR message other than that for
parameter initialization (with n001 set to
8 or 9).
Turn the Inverter
OFF and ON
after parameter
initialization with
n001 set to 8 or
9.
The Inverter processing data written
received a DSR message to write data.
Wait for an
elapse period
equivalent to 24
bits plus a
minimum of
10 ms to issue
the message
after a response
is received from
the Inverter.
A DSR message to a read-only register
was received.
Check and
correct the
register number.
Communications Chapter 7