D Output Open-phase Detection
(Parameters: n168, n169; Fault Display: LF)
This function detects open phases between the Inverter output and the motor.
D Ground Fault Detection (Fault Display: GF)
This function detects ground faults between the Inverter output and the motor.
D Load Short-circuit Detection (Fault Display: SC)
Prior to an Inverteroutput, this function detects whether the output is short-circuited.If short-circuiting
occurs during an output, it detects an overcurrent (oC).