7-42
Parameter Description
Next process Determines which step is to be processed next or
finishes the operation after the step is finished
normally.
Error processing Determines which step is to be processed next or
finishes the operation, if the step has an error.
H Data Created by Protocol Support Tool
·A project file is used by the Protocol Support Tool to create and control data.
A project file consists of the following data.
Single project file Protocol list Protocol name
Protocol name
Protocol name
A maximum of 20
protocols (A maximum of
1,000 sequences per
project)
Trace list
PC
Protocol name
(Single protocol)
Sequence 000/Sequence name
Sequence 001/Sequence name
Sequence 999/Sequence name
A maximum of 60
sequences/protocol
The first sequence
number and last
sequence number are
specified by each
protocol.
Send message list Message name
Message name
Recv message list Message name
Message name
A maximum
of 300
messages
Recv matrix Matrix name
Matrix name
A maximum
of 100
matrixes
Sequence #jjj
Step 00
Step 15
A maximum of 16 steps
Step 01
Note The standard system protocol incorporated by the Communications Board can-
notbeeditedortransferred.Tomakeuseofthestandardsystemprotocol,copyit
to the project file and edit it.
In 7-9-4 Creating a Project File, an example to create a new project file is shown
without making use of the standard system protocol.
Communications Chapter 7