EasyManua.ls Logo

Omron SYSDRIVE 3G3MV - Page 277

Omron SYSDRIVE 3G3MV
348 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-24
8-2-9 Controller or AM Radio Receives Noise when
Inverter is Started
·Noise derives from Inverter switching.
Take the following actions to prevent noise.
S Lower the carrier frequency of the Inverter in n080.
The number of internal switching times is reduced, so noise can be reduced to
some extent.
S Install an Input Noise Filter.
Install an Input Noise Filter on the power input area of the Inverter.
S Install an Output Noise Filter.
Install an Output Noise Filter on the output area of the Inverter.
S Use metal tubing.
Electric waves can be shielded by metal. Therefore, enclose the Inverter with a
metal tube.
8-2-10 Ground Fault Interrupter is Actuated when
Inverter is Started
·Leakage current flows through the Inverter.
TheInverterperformsinternalswitching.Therefore,aleakagecurrent flowsthrough
the Inverter. This leakage current may actuate the ground fault interrupter, shutting
the power OFF.
Useagroundfaultinterrupterwithahighleakage-currentdetectionvalue(sensitivity
amperage of 200 mA or more, operating time of 0.1 s or more) or one with high-fre-
quency countermeasures for Inverter use.
Reducing the carrier frequency value in n080 is also effective.
In addition, remember that a leakage current increases in proportion to the cable
length.Normally,approximately5mAofleakagecurrentisgeneratedforeachmeter
of cable.
Maintenance Operations Chapter 8

Table of Contents

Other manuals for Omron SYSDRIVE 3G3MV

Related product manuals