teristics
Control method
Sine wave PWM (V/f control)
Carrier frequency
2.5 to 10.0 kHz (in vector control)
Frequency control
range
0.1 to 400 Hz
Frequency
precision
(temperature
characteristics)
Digital commands: ±0.01% (--10°C to 50°C)
Analog commands: ±0.5% (25°C ± 10°C)
Frequency setting
resolution
Digital commands: 0.1 Hz (less than 100 Hz) and 1 Hz (100 Hz or
over)
Analog commands: 0.06 Hz/60 Hz (equivalent to 1/1000)
Output frequency
resolution
0.01 Hz
Overload capacity
150% of rated output current for 1 min
External frequency
set signal
Selectable with FREQ adjuster: 0 to 10 VDC (20 kW), 4 to 20 mA
(250 W), and 0 to 20 mA (250 W)
Acceleration/de-
celeration time
0.01 to 6,000 s (Independent acceleration and deceleration time
settings)
Braking torque
Approx. 20% (125 to 150% possible with braking resistor: 2 types)
Voltage/frequency
characteristics
Set voltage vector control/user V/f pattern
Specifications Chapter 9