10-9
Param-
eter
No.
Ref-
er-
ence
page
Changes
during
opera-
tion
Default
setting
Unit
of
set-
ting
Set-
ting
range
DescriptionNameRegis-
ter No.
n038 0126 Motor protec-
tive time
Used to set the electric thermal char-
acteristics of the motor to be con-
nected in 1-minute increments.
Note The default setting does not
require any changes in normal
operation.
Note Toset theparameter according
to the characteristics of the
motor, check with the motor
manufacturer the thermal time
constant and setthe parameter
with some margin. In other
words, set the value slightly
shorter than the thermal time
constant.
Note To detect motor overloading
quicker, reduce the set value,
provided that it does not cause
any application problems.
1 to 60 1 min 8 No 6-41
n039 0127 Cooling fan
operation
Used to operate the Cooling Fan of
the Inverter while the Inverter is
turned ON or only while the Inverter is
in operation.
0: Rotates only while RUN command
is input and for 1 minute after
Inverter stops operating
1: Rotates while Inverter is turned ON
Note Thisparameterisavailableonly
if the Inverter incorporates a
Cooling Fan.
Note Iftheoperationfrequencyofthe
Inverteris low,the life of thefan
canbeprolongedbysettingthe
parameter to 0.
0, 1 1 0 No 6-42
n040 0128 Direction for
motor rotation
0: CCW
1: CW
The motor output shaft rotates in the
counterclockwise (0”) or in the clock-
wise (”1”) direction with a forward in-
verter reference.
Note Applicable for software version
No. 010024 or later.
0, 1 1 0
List of Parameters Chapter 10