EasyManua.ls Logo

Omron ZEN - Comparing Timer;Counter Present Values Using Comparators (P); Settings in the Ladder Program Edit Screen

Omron ZEN
196 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
91
Comparing Timer/Counter Present Values Using Comparators (P) Section 3-11
3-11 Comparing Timer/Counter Present Values
Using Comparators (P)
Timer (T), holding timer (#), and counter (C) present values can be
compared. The present values of the same type of timer or counter
can be compared, or they can be compared to constants.
Operation
3-11-1 Settings in the Ladder Program Edit Screen
Comparator inputs are written in the Ladder Program Edit Screen.
Settings are made in the Parameter Settings Screen.
0
•Example 1
(When comparison setting is
holding timer #0 12 min 34 s)
•Example 2
(When comparison setting is
counter 1 (C1) counter 2 (C2))
Setting
12 min 34 s
Comparator
bit
#0 present value
Comparator
bit
C1 present value
C2 present
value
Comparator addresses P0 to Pf (16 points)
Comparator bit
Comparison result
output
Z211-E1-03.book Page 91 Friday, November 21, 2008 10:38 AM