Comparing Timer/Counter Present Values Using Comparators (P) Section 3-11
3-11-2 Settings in the Parameter Settings Screen
Note Press the ALT Button to switch between comparison data 2 timer/
counter address and constants.
Comparison type T: Timer
#: Holding timer
C: Counter
Comparison data 1 T: T0 to Tf Timers 0 to f
#: #0 to #7 Holding timers 0 to 7
C: C0 to Cf Counters 0 to f
* Size comparison between T
and T or T and constant.
* Size comparison between #
and # or # and constant.
* Size comparison between C
and C or C and constant.
2 T: T0 to Tf Timers 0 to f
#: #0 to #7 Holding timers 0 to 7
C: C0 to Cf Counters 0 to f
Constant: 00.00 to 99.99 when
comparison type is T/#
0000 to 9999 when comparison
type is C
Operator >=: Timer/counter comparator bit turns ON when comparison data 1
≥ comparison data 2.
<=: Timer/counter comparator bit turns ON when comparison data 1
≤ comparison data 2.
Monitor enabled/
disabled
A Operating parameters can be monitored and settings changed.
D Operating parameters cannot be monitored or settings changed.
• Comparing Holding Timers and
Constants
(When Holding Timer #0 ≥ 12 min
34 s)
• Comparing Counters
(When counter 1 (C1) ≤ counter 2
(C2))
Comparator
address
Comparison data 1
Comparison type
Monitor enabled/disabled
Operator
Comparison data 2
Comparator
address
Comparison data 1
Comparison type
Monitor enabled/disabled
Operator
Comparison data 2