152
Application Examples Appendix E
Program Example
Parameter Settings
Coin-operated Carwash (Holding Bits and Holding
Timer)
Application
The ZEN can be used to change the operating time of a machine, such as a coin-
operated car wash, depending on the number of coins inserted.
If a holding timer is used and holding bits used for the self-holding bits, the remaining
time will not be reset if there are unexpected power interruptions.
In this example, the carwash operates for 3 minutes if one coin is inserted, 6 minutes if
two coins are inserted, and 9 minutes if 3 coins are inserted.
A holding timer is used as the timer.
00
01
02
03
04
05
06
07
08
I0
I0
M0
M1
M2
I0
I0
M0
I1
[M0
[M1
[M2
[Q0
[Q1
[Q2
TT0
I1
I2
T0
Inputting alarm
Inputting buzzer stop
Testing lamp
Alarm lamp
Normal lamp
Flashing pulse timer
Buzzer
Flashing Pulse Timer
Set to flash at 0.5 s intervals.
Z211-E1-03.book Page 152 Friday, November 21, 2008 10:38 AM