Detecting and Managing Faults 19
Example of the show faulty command displaying a fault that was detected by
POST. These kinds of faults are identified by the message Forced fail reason,
where reason is the name of the power-on routine that detected the fault. For
more information, see “Managing Faults (POST)” on page 29.
Example of the show faulty command displaying a fault that was detected by
PSH. These kinds of faults are identified by the presence of a UUID value.
/SP/faultmgmt/0 | sunw-msg-id | SPT-8000-5X
faults/0 | |
/SP/faultmgmt/0 | uuid | 64d52ce4-614e-693f-bb71-ea3f829d
faults/0 | | ad73
/SP/faultmgmt/0 | timestamp | 2011-10-14/20:14:13
faults/0 | |
/SP/faultmgmt/0 | detector | /SYS/PS0/S1/V_IN_ERR
faults/0 | |
/SP/faultmgmt/0 | product_serial_number | 1030NND0D2
faults/0 | |
/SP/faultmgmt/0 | chassis_serial_number | 0000000-0000000000
faults/0 | |
->
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BOB1/CH0/D0
/SP/faultmgmt/0/ | timestamp | Oct 12 16:40:56
faults/0 | |
/SP/faultmgmt/0/ | sp_detected_fault | /SYS/MB/CMP0/BOB1/CH0/D0
faults/0 | Forced fail(POST)
-> show faulty
Target | Property | Value
--------------------+------------------------+--------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB
/SP/faultmgmt/0/ | class | fault.fruid.replay
faults/0 | |
/SP/faultmgmt/0/ | sunw-msg-id | PCIEX-8000-8R
faults/0 | |
/SP/faultmgmt/0/ | uuid | c448cc2b-9f9e-4ae7-c494-c8fe99ed
faults/0 | | dd58
/SP/faultmgmt/0/ | timestamp | 2011-08-29/16:31:51
faults/0 | |
/SP/faultmgmt/0/ | chassis_serial_number | *******-**********
faults/0 | |
/SP/faultmgmt/0/ | product_serial_number | **********
faults/0 | |