Servicing Memory 87
c. Switch to the host console to view POST output.
Watch the POST output for possible fault messages. The following output
indicates that POST did not detect any faults:
Note – The server module might boot automatically at this point. If so, go directly to
Step e. If it remains at the ok prompt go to Step d.
d. If the server module remains at the ok prompt, type boot.
e. Return the virtual keyswitch to Normal mode.
f. Switch to the host console and type the Oracle Solaris OS fmadm faulty
command.
If any faults are reported, see the diagnostics instructions in “Oracle ILOM
Troubleshooting Overview” on page 12.
5. Switch to the Oracle ILOM command shell.
-> start /HOST/console
.
.
.
0:7:2>INFO:
0:7:2> POST Passed all devices.
0:7:2>POST: Return to VBSC.
0:7:2>Master set ACK for vbsc runpost command and spin...
-> set /SYS keyswitch_state=Normal
Set ‘ketswitch_state’ to ‘Normal’
# fmadm faulty