EasyManua.ls Logo

Oracle Netra SPARC T4-1B

Oracle Netra SPARC T4-1B
142 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
88 Netra SPARC T4-1B Server Module Service Manual June 2012
6. Type the show faulty command.
If the show faulty command reports a fault with a UUID go to Step 7.Ifshow
faulty does not report a fault with a UUID, you have completed the verification
process.
7. Switch to the host console and type the fmadm repair command with the
UUID.
Use the same UUID that was displayed from the output of the Oracle ILOM show
faulty command.
Related Information
“Remove a DIMM” on page 80
“Install a DIMM” on page 81
“DIMM Configuration” on page 77
-> show faulty
Target | Property | Value
--------------------+------------------------+-------------------------------
/SP/faultmgmt/0 | fru | /SYS/MB/CMP0/BOB0/CH1/D0
/SP/faultmgmt/0 | timestamp | Dec 14 22:43:59
/SP/faultmgmt/0/ | sunw-msg-id | SUN4V-8000-DX
faults/0 | |
/SP/faultmgmt/0/ | uuid | 3aa7c854-9667-e176-efe5-e487e520
faults/0 | | 7a8a
/SP/faultmgmt/0/ | timestamp | Dec 14 22:43:59
faults/0 | |
# fmadm repair 3aa7c854-9667-e176-efe5-e487e520

Table of Contents

Related product manuals