4-8 System Programming
4.1.1 Slot Assignment
Specifies the length of time in seconds the system
requires to confirm the disappearance of the bell signal
from local Central Office.
Dial Pulse Signal type is fixed to “Type-A: Normal.”
Specifies DTMF Inter Digit Pause Time.
Specifies the length of time in milliseconds the system
requires to determine that the received signal is the bell
signal.
Specifies the length of Flash signal which the system
sends to the local Central Office.
[Note]
• This setting is valid when Group-Trunk Group
“Hooking Time”(See Section 4.3.1) is set to “80 ms.”
• This setting is required when Hooking Time required
by the local Central Office is not listed in Trunk
Group “Hooking Time” assignment.
Used to adjust the volume level of the call.
Specifies the pulse break time for pulse digits.
Activates or deactivates the detection of caller ID
signals transmitted from the Central Office.
Parameter
Value Range
(default)
Description/Function Reference
1 - 15 sec
(5)
1.
Type-A: Normal
2.
Type-B: New
Zealand
3.
Type-C: Sweden
(Type-A)
64 - 304 msec
in 16 msec
increments
(112)
24 - 1200 msec
in 24 msec
increments
(144)
16 - 4080 msec
in 16 msec
increments
(80)
-3dB - +3dB
in 0.5 increments
(0)
-16 - +16 msec
(0)
1. Yes
2. No
(Yes)
Bell
Disappearance
Timer
Pulse Type
DTMF Inter
Digit Pause
Time
Bell Detection
Time
Flash Time
Gain
Adjustment
Pulse Break
Time
Adjustment
Caller ID
Detection