System Programming 4-7
4.1.1 Slot Assignment
On outgoing CO calls, the system waits at least 1.0
second after seizing the CO line, before sending the
dialing digits to the Central Office by default.
This allows the Central Office enough time to accept
the dialing digits correctly.
Specifies the appropriate value depending on the
requirements of your local Central Office.
Specifies the % break for pulse digits.
This is the ratio between on and off hook signals during
digit transmission.
On outgoing outside calls, dialed number is toned out,
which informs the extension user that dialed number
has been dialed out. Dialed number is toned out by
default. Select “No” to turn off the click tone.
Used to distinguish between each pulse signal. To meet
the requirements of your Central Office, select the
appropriate value that represents the delay between dial
pulses.
(This setting is only required when using dial pulse
trunks.)
4.1.1.2 Properties (ELCOT)
Used to set the parameters for the ELCOT card.
Parameter
Value Range
(default)
Description/Function Reference
0.5 - 8.0 sec in
0.5 sec
increments
(1.0)
1. 60 %
2. 67 %
(60)
1. Yes
2. No
(Yes)
1. 630 msec
2. 830 msec
3. 1030 msec
(830)
First Dial Timer
% Break
Click Tone
Pulse Inter Digit
Pause