2.5.1 E&M Card (KX-T96184)
• Insert this card into a free slot.
1) Connection of the E&M Line cord (twisted cable)
• Connect the ground wire to the ground wire connector (GND).
• Insert the 50-pin connector (plug) of the E&M Line cord (twisted cable) into the 50-pin con-
nector (jack) on the E&M card. See Section 2.1.4 “Amphenol 57JE type connector.”
2) Connection of cable pins
See Section 2.5.9 “Cable Pin Numbers for E&M Lines.”
2.5 Trunk Cards