214
Timer Programming
DISA Prolong Time *
-
Description
Sets the maximum allowable prolonged time for a DISA CO-to-CO
call. A CO-to-CO call is initially limited by the “CO-to-CO Call
Duration Time” (Program [206]). However, the DISA caller can
prolong the call after hearing the warning tones by pressing any key
(except the * key). This parameter, the “DISA Prolong Time,”
sets the duration of these extended periods.
Selection
Time (minutes): 0
through 7
(O=no prolonging)
Default
3min
Programming
1.
Enter 214.
Display: DI%_A Prolng Time
2.
Press
NEXT.
Display exazgle: Time:3 min
3.
Enter the time.
To
change the current entry, enter the new time.
4.
Press
STORE.
5.
Press
END.
Conditions
l
Do not confuse this parameter with the “CO-to-CO Call Duration
Time” (Program [206]) parameter.
l
Program [206] “CO-to-CO Call Duration Time” is used to set the
duration time allowed for a CO-to-CO call.
. You cannot leave the entry empty.
Feature References
Section
3,
Features,
Direct Inward System Access (DISA)
(‘7
_>
#- -.
4-64
System Programming
*: Available for KX-TD 1232 only.