System Programming
UCD
Over-ow
Description
Assigns the destination where the call is transferred to when all
extensions in the UCD group are busy. The Time Table number of
the ovefflow extension must also be assigned.
Selection
l
UCD group number:
1 through 8
l
Overflow
extension number: 2
through 4 digits
l
Time table number:
1
through 4
Default
All UCD groups - Not stored
Programming
1.
Enter 122.
Display: 122 UCD OVERFLOW
2.
Press
NEXT.
Display:
UCD No?+
3.
Enter a
UCD group number.
To
enter
UCD
group number
1, you can also press NEXT.
Display example: UCDl:
,TT:
4.
Enter a
overflow extension number.
Display example: UCDl:lOZ,TT:
5.
Press *
.
4.
Enter a time
table number.
Display example: UCDl:lOZ,TT:l
4.
Press
STORE.
5.
Press
END.
Conditions
If the ovefflow extension or Time Table number is not assigned, the
system does not answer the call and waits for any extension to be idle. In
this case, IRNA will be employed.