SVM Cyclic Tone Option—Tone On Maximum Time
Specifies
the maximum duration of the cyclic tone that will be recognized by the PBX. When the tone sent from
the telephone company is shorter than the value set here, the PBX recognizes it as a tone-on.
Note that this option can only be set when
SVM Cyclic Tone Detection on this screen is set to "Option".
To apply changes to this setting, follow the steps below:
1. Change this setting.
2. Set the status of the
SVM/ESVM card (KX-TDA50) or OPB3 card (KX-TDA100/KX-TDA200/KX-TDA600)
to "OUS", then "INS".
Default
600 ms
Value Range
20 ´ n (n=6–200) ms
Maintenance Console Location
7.5 [5-3-3] Voice Message—SVM
Programming Manual References
3.1 [1-1] Slot
Feature Manual References
16.1.5 SVM (Simplified Voice Message)
SVM Cyclic Tone Option—Tone Off Maximum Time
Specifies
the maximum time that the PBX waits for a cyclic tone to be sent from the telephone company before
recognizing it as a tone-off. When no tone is detected within the time set here, the PBX recognizes it as a
tone-off.
Note that this option can only be set when
SVM Cyclic Tone Detection on this screen is set to "Option".
To apply changes to this setting, follow the steps below:
1. Change this setting.
2. Set the status of the
SVM/ESVM card (KX-TDA50) or OPB3 card (KX-TDA100/KX-TDA200/KX-TDA600)
to "OUS", then "INS".
Default
600 ms
Value Range
20 ´ n (n=6–200) ms
Maintenance Console Location
7.5 [5-3-3] Voice Message—SVM
Programming Manual References
3.1 [1-1] Slot
Document Version 2010-11 PC Programming Manual 673
7.5 [5-3-3] Voice Message—SVM