SLT Off Hook Guard Time
Specifies
the length of guard time used for off-hook signals from SLTs, to prevent the PBX mistaking them for
pulse dials.
Default
504 ms
Value Range
8 ´ n (n=12–63) ms
Maintenance Console Location
3.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Manual References
None
SLT Pulse Maximum Break Width
Specifies the maximum length of the break signal in a pulse dial.
Default
96 ms
Value Range
8 ´ n (n=9–20) ms
Maintenance Console Location
3.4 [1-1] Slot—Card Property - Extension Type
Programming Manual References
None
Feature Manual References
None
SLT Pulse Minimum Make Width
Specifies the minimum length of the make signal in a pulse dial.
Default
8 ms
82 PC Programming Manual Document Version 2010-11