3 Operating Mode
Operating ModeOperating Mode
Operating Mode
07-02-12-02-EN-V1215.doc / Type: 638
47
3.3 Configurable Pin Functions (Operating Mode Dependent)
Input Functions (Operating Mode Dependent)
Input
Nr.
Function
F0
Function
F1
Function
F2
Function
F3
Function
F4
Function
F5
Function
F6
2)
Input
X10.14
3)
limit switch +
1)
set selection
data 2
0
move manually
+
CAN
Node no.
2
0
Input
X10.15
3)
limit switch -
1)
set selection
data 2
a
move manually
-
CAN
Node no.
2
a
Input
X10.4
latch input 1
ִ
extended
latch
1)
set selection
data 2
b
CAN
Node no.
2
b
Input
X10.25
latch input 2
ִ
1)
set selection
data 2
c
CAN
Node no.
2
c
Input
X10.11
start (slope 0-
>1) for BIAS -
move
commands
3)
regulator
trouble reset
1)
set selection
data 2
d
CAN
Node no.
2
d
Input
X10.24
operating mode
selection
(0) – 1or 2
(3) – 1or 4
3)
reference
sensor
1)
set selection
data 2
max
CAN
Node no.
2
max
Input
X10.2
start (slope 0
-->1)
with position set
selection in
position control (4)
strobe
(slope 0-->1)
for BIAS-set
selection
Output
X10.12
position
reached
reference
output
tracking
window
exceded
synchron-
format
trigger
no
drive
trouble
-
Output
X10.13
temperature
monitoring
reference
output
tracking
window
exceded
start offset
trigger
no
regulator
trouble
-
Output
X10.20
warning reference
output
tracking
window
exceded
no
drive
trouble
-
Output
X62.3
X62.4
active ok
(motor brake)
reference
output
tracking
window
exceded
no
drive
trouble
-
BIAS function is freely programmable in operating mode 5. - No function in operating modes 0 to 4.
ִ Fast input for optimal timing.
1) With every row (from the top to the bottom) in which the function F2 is assigned to an input, the binary
value (2
n
) increases by 1. (See example)
Operating mode 4: Only numbers 0 - 9 are allowed to be set!
2) Only possible with module RP-CAN.
3) If the Option RP 2C8 / PC8 (
See: Fieldbus - interface - COM2-COM3) is inserted, the contact functions
as described for the X10-plug are not valid. The inputs are freely programmable utilizing the BIAS
program.