Parker Hannifin S.p.A. Divisione S.B.C. user’s manual TWIN-N and SPD-N
144
[0x6067] 'Position window': in user units converted by mean of position factor and compared
with the motor position to check if target reached in profile position and
interpolated position modes.
[0x6068] 'Position window time': resolution of 1.024 msec per unit
[0x607a] 'Target position': in user units converted by mean of position factor and used in
profile position mode (in this mode some elements of CAM tab 0 are used as spare
memory and so affected by changes).
[0x607c] 'Home offset': in position units converted by position factor
[0x6081] 'profile velocity': profile velocity in profile position mode(in counts/sec o RPM
depending on unit selection (standard or not) with b272.1)
[0x6083] 'profile acceleration': acceleration of profile in profile position mode (in
counts/sec^2 or ms/kRPM depending on unit selection (standard or not) with
b272.1)
[0x6084] 'profile deceleration': deceleration of profile in profile position mode (in
counts/sec^2 or ms/kRPM depending on unit selection (standard or not) with
b272.1)
[0x6085] 'quick stop deceleration': deceleration in quick stop action
[0x6086] 'Motion profile type': valid values 0.
[0x6093][1] 'Position factor': Numerator position factor
[0x6093][2] 'Position factor': Denominator position factor
[0x6094][1] 'Velocity encoder factor': Numerator velocity factor
[0x6094][2] 'Velocity encoder factor': Denominator velocity factor
[0x6097][1] 'Acceleration factor': Numerator acceleration factor
[0x6097][2] 'Acceleration factor': Denominator acceleration factor
[0x6098] 'Homing method': all standard values available.
[0x6099][1] 'Homing speeds': searching sensor velocity (in counts/sec or RPM depending on
unit selection (standard or not) with b272.1)
[0x6099][2] 'Homing speeds': searching index velocity (in counts/sec or RPM depending on
unit selection (standard or not) with b272.1)
[0x609a] 'Homing acceleration': acceleration homing (in counts/sec^2 or ms/kRPM depending
on unit selection (standard or not) with b272.1)
[0x60c0] 'Interpolation sub mode selection': valid values 0(linear interpolation),-1(cubic
interpolation with position and velocity) , -2 (cubic interpolation with position)
[0x60c1][1] 'Interpolation data record': INTEGER32 interpolator position reference
[0x60c1][2] 'Interpolation data record': INTEGER32 interpolator velocity reference in
counts/sec
[0x60c1][3] 'Interpolation data record': INTEGER32 interpolator velocity reference in RPM
[0x6502] 'Supported drive modes': see (see 0x6060)
[0x6504] 'Drive Manufacturer': "Parker Hannifin div. SBC Italy"
[0x6505] 'http drive catalog address': "*** http://www.sbcelettronica.com ***
http://www.parker-eme.com ***"
Following modes of operation of dsp 402 are implemented beside the device control state
machine:
Homing mode
Profile position mode
Interpolated position mode