Parker Hannifin S.p.A. Divisione S.B.C. user’s manual TWIN-N and SPD-N
64
Par. Descrizione Campo Def. Tipo/
Note
Pr207 Overvoltage limit. If b39.1=1, overvoltage and braking
alarm. This value decides the braking limit and the
overvoltage alarm. It’s important to know well the
characteristics of the drive before setting this value for
avoid serious damages to the drive.
-32767÷
+32767
R/W
M
Pr208 Braking resistance.. In “Ω”. 40 R/W
M
Pr209 Power of the braking resistance. In “W”. 120 R/W
M
Pr217
Selection (0) synchronous motor (1) asynchronous
motor. 0: rotative brushless motor, 1: asynchronous motor 4
poles to vectorial control with sensor.
0÷1 0 R/W
M
Pr218 Base_speed_asinc. Asynchronous motor speed in
synchronism conditions.
[rpm] 0 R/W
M
Pr219 SLIP_ASINC. Asynchronous motor slip.
0÷32767
[rpm]
0
R/W
M
Pr220
MAGN_CURR_ASINC. Asynchronous motor
magnetizing current.
2
cos-1 Pr33 220Pr ×=
0÷32767
[A]
0
R/W
M