Parker Hannifin S.p.A Divisione S.B.C. user’s manual TWIN-N and SPD-N
98
b181.9
Enable counter position from CAM1 to global counter(Pr130:131). This
command, b181.9=1, enable the reference of CAM1. This value is added
algebraically to global counter of reference.
b181.10
Enable counter position from CAM 2 to global counter(Pr130:131). This
command, b181.9=1, enable the reference of positioner. This value is added
algebraically to global counter of reference.
b181.11
Enable counter position from trapezoidal positioner to global counter
(Pr130:131). This command, b181.9=1, enable the reference of CAM2. This value
is added algebraically to global counter of reference.
b181.13
Enable counter position from CAM 1 to reference position (Pr60:61).
b181.14
Enable counter position from CAM 2 to reference position (Pr60:61).
b181.15
Enable counter position from trapezoidal positioner to reference position
(Pr60:61).