51-4
1
Servicing Hydraulic Systems
1. Locate the hydraulic suction 󰘰lter and gauge
within the engine canopy.
2. Observe all safety warnings.
3. The 󰘰lter housing has an internal shut o󰘯 valve
to permit the 󰘰lter to be changed.
4. Close down the machine and implement the
lockout procedure.
5. Make sure the oil has cooled before changing a
󰘰lter.
NOTICE
The hydraulic 󰘱uid 󰘰lters have condition
indicators to show when the 󰘰lter element
needs to be renewed.
When the gauge changes from green to
red whilst the system is running at normal
operating temperature the 󰘰lter must be
renewed.
In cold ambient temperatures the 󰘰lter
indicators may show an incorrect red
condition until the system reaches normal
operating temperature.
n WARNING
Refer to Safety Notices Section for relevant
warning and procedure
LOCKOUT
PLANT
SKIN INJECTION
HAZARD
n DANGER
Refer to Safety Notices Section for relevant
warning and procedure
Suction Filter

Table of Contents