217
High-voltage Cutoff Method
Repair of High Voltage Cutoff
During Maintenance
1. Shift the gear in Park (P), with the
vehicle in a non high-voltage state and
the vehicle stationary. Open the front
compartment hood, pull out the red 10A
BECM fuse, close the doors, press the
smart key lock button/car search button
and put the vehicle power mode to OFF
position. Wait at least 5 minutes to
ensure the high-voltage system is
completely powered off;
2. Disconnect the low-voltage repair switch
in the front compartment;
3. Open the driver door and remove the
cover under the front centre console as
shown. Disconnect the negative cable
from the negative terminal of the low-
voltage battery.
Always wear personal protective
equipment and disconnect the high-
voltage system if it is necessary to touch
any high-voltage harnesses or components.
Do not touch power battery components
even after disconnecting the high-voltage
system to avoid the risk of death by electric
shock.
Emergency High-voltage Cut-off
During Rescue
During rescue operations, in case there is a
voltage leakage or an uncertainty whether
the high-voltage has been disconnected,
use scissors or diagonal pliers to cut the
harness to realize the emergency cutoff of
the high voltage power and avoid secondary
injuries to the trapped or rescued personnel.
Cutting Point in the Front Compartment
1. Open the front compartment hood;
2. Use scissors or diagonal pliers to cut the
harness at the shown locations to
Emergency Rescue