Rectangular Broad Crested Weir Calculations 
Calculations  
Absolute 
If the flow calculation is to be absolute P702 = 1 the flow will be calculated 
using the formula:  q = (2/3)
1.5
 C
e
b(gh
3
)
0.5
 
 
Where:   
q   = flowrate            
Ce = discharge coefficient calculated by Ultra 4 P723           
b   = approach width P710  
g   = gravitational acceleration (nominal value = 980.66 cm/s
2
)                                                                                     
h  = head  
 
Ratiometric 
If the flow calculation is to be ratiometric P702 = 2 the flow will be 
calculated using the formula: q= q
cal
C
e
/C
ecal
(h
e
/h
ecal
)
1.5
 
Where:   
q        =   flowrate  
q 
cal    
= flowrate at maximum head P705                          
Ce   = discharge coefficient calculated by Ultra 4 P723  
Ce
cal
  = discharge coefficient at maximum head    
he      = effective head                           
he
cal
   = effective head at maximum head