How to Adjust the Sealing Water Flow
Before you adjust the sealing water flow, make sure that the brushes and sponge are
clean.
To adjust the sealing water flow:
1. Set the water flow using the back lever.
When standing in front of the feeder:
- Push the lever towards the left-hand side to increase the water level.
- Push the lever towards the right-hand side to decrease the water level.
How to Clean the Feeder Belts and Rollers
Follow the steps below to clean the belts and rollers of the feeder and of the Dynamic
Scale (if installed).
To clean the feeder belts and rollers:
1. Open equipment covers; in the Mixed-Size Feeder, press the left of the upper blue
handle to release and lift up the drive assembly.
2. Clean the belts and/or rollers with a damp cloth or 70° alcohol on a cotton
applicator.
3. Push down the upper drive assembly until it locks back into position and close the
feeder cover.