Remote Control
R&S
®
FPC
313User Manual 1178.4130.02 ─ 07
CALCulate<n>:ADEMod:LIMit:SELect <Filename>
This command selects a set of limit values for AM and FM measurements.
Selecting a set of limit values automatically initiates a limit check of the numerical
results.
Suffix:
<n>
.
irrelevant
Parameters:
<Filename> String containing the file name of the limits definition file.
The file extension is either .amlim (AM limits) or .fmlim (FM
limits).
Example: //Load limit values for AM measurement
CALC:ADEM:LIM:SEL 'limits.amlim'
Manual operation: See "Select Limits" on page 390
19.15 Remote Commands of the Digital Demodulation
Measurements and Result Displays......................................................................313
Measurement Configuration..................................................................................318
Frequency............................................................................................................. 320
Amplitude.............................................................................................................. 320
Sweep Control.......................................................................................................322
Trigger...................................................................................................................322
Marker...................................................................................................................323
19.15.1 Measurements and Result Displays
CALCulate<n>:FEED..................................................................................................... 313
CALCulate<n>:MARKer:FUNCtion:DDEMod:CARRier[:RESult]?........................................ 314
CALCulate<n>:MARKer:FUNCtion:DDEMod:CFDRift[:RESult]?..........................................314
CALCulate<n>:MARKer:FUNCtion:DDEMod:CFERror[:RESult]?........................................ 315
CALCulate<n>:MARKer:FUNCtion:DDEMod:MDEPth[:RESult]?......................................... 315
CALCulate<n>:MARKer:FUNCtion:DDEMod:MDEViation[:RESult]?.................................... 315
CALCulate<n>:MARKer:FUNCtion:DDEMod:MERRor[:RESult]?.........................................316
CALCulate<n>:MARKer:FUNCtion:DDEMod:MINDex[:RESult]?..........................................316
CALCulate<n>:MARKer:FUNCtion:DDEMod:MOERror[:RESult]?........................................316
CALCulate<n>:MARKer:FUNCtion:DDEMod:MPOWer[:RESult]?........................................317
[SENSe:]DDEMod..........................................................................................................317
[SENSe:]DDEMod:FSK:OFFSet?.....................................................................................317
TRACe[:DATA]?.............................................................................................................318
CALCulate<n>:FEED <ResultDisplay>
This command selects the result display.
Remote Commands of the Digital Demodulation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FPC Series and is the answer not in the manual?

R&S FPC Series Specifications

General IconGeneral
BrandR&S
ModelFPC Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals