Loading...
26 January, 2001 FUSING
3-53
Replacement
Adjustment
– Right side –
1. Two terminals [A] (! x2)
2. Spring [B]
3. Connector bracket [C] (! x2)
4. Bracket [D] (! x2)
NOTE: To avoid breaking the fusing lamps, handle them with care. Avoid
touching the lamps with your fingers. Note the top/bottom positioning of
the fusing lamps as you remove them. The sizes of the holes in the
holder match the sizes of the ends of the 650 W lamp (red) and 550 W
lamp (brown).
5. Remove both fusing lamps.
B004R607.WMF
[A]
[B]
[C]
[D]