SERVICE PROGRAM MODE 26 January, 2001
5-36
SP6-xxx: Peripherals
SP6 Mode Number Function and [Setting]
6006* DF Registration Adjustment Adjusts the side-to-side and leading edge
registration for simplex and duplex original
feeding in ARDF mode. Press ! to toggle ±.
1* Side-to-side
[–3 ~ +3 / 0.0 / 0.1 mm step]
2* Leading Edge (Thin Original)
[–30 ~ +30 / 0.0 / 0.17 mm step]
3* Leading Edge (Duplex Front)
4* Leading Edge (Duplex Rear)
[–42 ~ +42 / 0.0 / 0.12 mm step]
6007 ADF Input Check
1 Group 1
2 Group 2
Displays the signals received from sensors and
switches of the ARDF.( 5.1.4)
6008 ADF Output Check
Switches on each electrical component (ARDF
motor, solenoid, etc.) of the ARDF for testing. (
5.1.5)
Press # to switch on or $ to switch off.
6009 DF Free Run
1 Duplex Mode
2 Stamp Mode
Performs a free run with the ARDF for duplex and
stamp testing. Input the number for the item you
want to check, and then press # to start.
1: To Start, 0: To cancel
This is a general free run controlled from the
copier. For more detailed free run modes, see the
ARDF manual.
6010* DF Stamp Position
Adjustment
Adjusts the horizontal position of the stamp on the
scanned originals.
[–7~+7 / 0 / 0.5 mm steps]
Sets detection of an original size that is larger
than the size above the size assigned to the
original detection sensor which otherwise may not
be possible. This provides an alternate selection
for detection, other than that assigned with SP5-
131.
0 / 1
0: Allows settings shaded in table below.
1: Allows settings not shaded in table below.
Setting
Bit 0 1
7 A4 (L) LT (L)
6 11” x 15” DLT (L)
5 DLG (L) 11” x 15”
4 LT (S) US Exec (S)
3 LT (L) 8* x 10” (L)
2 LG (L) F4 (L)
1 A4 (L) 16K (L)
6016*
Original Size Decision
Priority
0 8K (L) DLT (L)
6017* Sheet Through Magnification Adjusts the magnification in the sub-scan
direction for ADF mode.
[–50.0 ~ +50.0 / 0.0 / 0.1%/step]
Use the ! key to toggle between + and - before
entering the value

Table of Contents