26 January, 2001 ANTI-CONDENSATION HEATER
1-53
Installation
1.14 ANTI-CONDENSATION HEATER
1. Remove the ARDF and exposure glass.
NOTE: For details about how to remove the ARDF and exposure glass, see
section “3 REPLACMENT AND ADJUSTMENT”, sections 3.9.1 and
3.9.2.
2. Remove the rear cover [A] of the scanner
unit (! x2, # x1)
3. Remove the knockout [B]
4. Push the 1st and 2nd scanners [C] to
the right.
5. Lift the harness guide [D]
6. Install the heater brackets [E] (! x2,
M3x6).
NOTE: Use the screws already attached
at the same position.
7. Install the heater [F] (! x2, M4x6) and
route the harness.
B004I204.WMF
B004I205.WMF
B004I206.WMF
[A]
[B]
[C]
[D]
[E]
[F]