SERVICE CALL CONDITIONS 19 January, 2001
4-10
Code No. Symptom Possible Cause
Communication break error between
BICU and LCT
627 C
The BICU cannot communicate with the
LCT unit normally as a result of
receiving a break signal.
Serial line connecting BICU and LCT
unit unstable
External noise
BICU board and LCT main board
connection defective or loose
LCT interface board defective
BICU board defective
SC630 Communication failure with CSS
(RSS)
630 D
The communication from the copier
was detected as abnormal at the CSS
center. This error occurs when the
acknowledge signal from the LADP
does not complete normally.
Occurred with a SC call, CC call,
Supply Management call, User call,
or CE call.
Timeout while no response from the
LADP, and signal on the RS-485 line
between PI and LADP is abnormal.
BICU control data transfer sumcheck
error
640 D
A sampling of control data sent from the
BICU to the controller reveals a
sumcheck error. Only the logging count
is performed.
Controller board defective
External noise
BICU board defective
BICU control data transfer abnormal641 D
A sampling of the control data sent from
the BICU reveals an abnormality.
Controller board defective
External noise
BICU board defective
Engine response error670 B
After powering on the machine, a
response is not received from the
engine within the specified time.
BICU installed incorrectly
BICU defective
Controller board defective
Controller-to-operation panel
communication error at startup
672 B
After powering on the machine, the
communication circuit between the
controller and the operation panel is not
opened, or communication with
controller is interrupted after a normal
startup.
Controller stall
Controller board installed incorrectly
Controller board defective
Operation panel connector loose or
defective
GAVD block I
2
C bus error690 A
An error is detected in the GAVD
communication I
2
C control register of
the GABIC2.
I2C bus on BICU defective
GAVD FCI block I
2
C bus error691 A
An error is detected in the FCI
communication I
2
C control register of
the GABIC2.
I2C bus on BICU defective
CDIC GAVD block I
2
C bus error692 A
An error is detected in the CDIC
communication I
2
C control register of
the GABIC2.
I2C bus on BICU defective