System Service Mode
D115/D116 3-2 SM Appendix
1103*
Fusing Idling
[0 = No / 1 = Yes]
1103 1
Enables or disables the contact-release control. The following table lists the
results.
Setting 0 = No 1 = Yes
C-R control Works Does not work
Idling time Shorter Longer
Fusing quality Lower Higher
1105*
Fusing Temp Adj
Adjusts the target fusing temperature. Note that the thermistor is at the center
of the hot roller.
1105 1 Warm Up-Center
[140 to 180 / 160 / 1°C/step]
1105 3 Standby-Center
[140 to 160 / 150 / 1°C/step]
1105 5 Copying-Center
[140 to 180 / 160 / 1°C/step]
1105 7 Low Level 2-Center
[0 to 80 / 60 / 1°C/step]
1105 9 Thick-Center
[140 to 185 / 165 / 1°C/step]
1106
Display Fusing
1106 1 (Center) Displays the fusing temperature.
1107*
Fusing Soft Start DFU
Adjusts the number of zero-cross cycles of the fusing lamp AC supply needed
to bring the fusing lamp power to 100% while bringing the lamp up to the
standby temperature or while copying. Increase this value if the machine is
experiencing sudden power dropouts.
1107 1
Warm Up Soft
Start
[0 = 10 times / 1 = 20 times / 2 = 50 times]