System Service Mode
SM Appendix 3-3 D115/D116
Appendix:
SP Mode
Tables
1107 2 Other Soft Start
[0 = 10 times / 1 = 20 times / 2 = 50 times / 3 = 1 time]
1107 3 Soft Stop Setting
[0: No / 1: Yes]
1108*
Set-Fusing Start
[0 = 1s / 1 = 1.5s / 2 = 2s]
1108 1 Specifies the interval for fusing-temperature control.
1109
Nip Band Check
1109 1
Conducts the nip band check (
"Adjusting Nip Band" in the section
"Replacement and Adjustment").
1110*
Fan Control Timer
[30 to 60 / 30 / 1 s/step]
1110 1
Specifies the fan control time. The fan motor keeps its operating speed for the
specified time before changing the speed or stopping. The fan control timer
prevents the exhaust fan from suddenly stopping. This function protects the
copier from overheating.
1159*
Fusing Jam SC
[0 = No / 1 = Yes]
1159 1
Enables or disables consecutive jam detection at the fusing unit. If this SP is
set to "1" (default: 0), consecutive fusing jam alarm occurs (SC559) when the
machine detects three consecutive paper jams at the fusing unit.
1902
Display-AC Freq.
1902 1
Displays the fusing lamp power control frequency (as detected by the zero
cross signal generator). The displayed value is 1/5 the actual frequency: 10
and lower = 50 Hz, 11 and higher = 60 Hz.