System Service Mode
SM Appendix 3-9 D115/D116
Appendix:
SP Mode
Tables
2922*
Toner Supply Time
[0.1 to 5.0 / 0.6 / 0.1 s/step]
2922 1
Adjusts the toner supply time. The toner supply motor remains on for the
specified time. To validate this setting, select "0" in SP2-921-001. Specify a
greater value if the user tends to make many copies having high proportions
of solid black image areas.
2926*
Standard Vt
[0.00 to 5.00 / 2.50 / 0.01 V/step] DFU
2926 1
Adjusts Vts (the Vt value for new developer). The TD sensor output is
adjusted to this value during the TD sensor initial setting process. This SP is
effective only when SP2-921001 is "0", "1", or "2".
2927*
ID Sensor Control
[0 = No / 1 = Yes]
2927 1
Determines whether the ID sensor signal is referenced or not for the toner
density control. Keep the default value in usual operations.
2928
Toner End Clear
2928 1
Clears the following messages and counters without supplying the toner:
Toner near end message
Toner end message
Toner near end counter
Toner end counter
Do not use this SP in usual operations. When the toner in the development
unit is abnormally insufficient, the drum may attract the toner carrier to its
surface. The toner carrier damages the drum surface..
2929*
Vref Limits Adjust the upper or lower Vref limit.
2929 1 Upper
[0.50 to 3.50 / 3.20 / 0.01V/step] DFU
2929 2 Lower
[0.50 to 3.50 / 0.70 / 0.01V/step] DFU