System Service Mode
D115/D116 3-22 SM Appendix
4936*
Gray Scale Image Adjust
001
Main Scan MTF Level
[0 to 15 / 0 / 1/step]
Adjust the MTF level for the main scan. This setting is only activated for the
specified mode with SP4-921-004.
0: None, 1: Level 1 to 15: Level 15
002
Main Scan MTF Strength
[0 to 5 / 0 / 1/step]
Adjust the MTF strength for the main scan. This setting is only activated for
the specified mode with SP4-921-004.
0: 1, 1: 1/32, 2: 1/16, 3: 1/8, 4: 1/4, 5: 1/2
003
Sub Scan MTF Level
[0 to 13 / 0 / 1/step]
Adjust the MTF level for the sub scan. This setting is only activated for the
specified mode with SP4-921-004.
0: No, 1: Level 1 to 13: Level 13
004
Sub Scan MTF Strength
[0 to 5 / 0 / 1/step]
Adjust the MTF strength for the sub scan. This setting is only activated for the
specified mode with SP4-921-004.
0: 1, 1: 1/32, 2: 1/16, 3: 1/8, 4: 1/4, 5: 1/2
005
Smooth Level
[0 to 7 / 0 / 1/step]
Adjust the smooth level. This setting is only activated for the specified mode
with SP4-921-004.
0: None, 1: Level 1 to 7: Level 7
006
Brightness
[0 to 255 / 128 / 1/step]
Adjust the brightness level. This setting is only activated for the specified
mode with SP4-921-004.
007
Contrast
[0 to 255 / 128 / 1/step]
Adjust the contrast level. This setting is only activated for the specified mode
with SP4-921-004.