System Service Mode
D115/D116 3-38 SM Appendix
128 Interval :Others
[250 to 10000 / 1000 / 1 /step]
132 Interval :A3
133 Interval :A4
134 Interval :A5
141 Interval :B4
142 Interval :B5
160 Interval :DLT
164 Interval :LG
166 Interval :LT
172 Interval :HLT
5508*
Auto Call Setting CTL -
001*
Jam Remains
0: Disable, 1: Enable
Enables/disables initiating a call for an unattended paper jam.
002*
Frequent Jams
0: Disable, 1: Enable
Enables/disables initiating a call for consecutive paper jams.
003*
Door Open
0: Disable, 1: Enable
Enables/disables initiating a call when the front door remains open.
011*
Jam Remains: Time
[ 03 to 30 / 10 / 1 minute /step]
Sets the time a jam must remain before it becomes an "unattended paper
jam". This setting is enabled only when SP5508 004 is set to 1.
012*
Freq Jam: # of Time
[ 02 to 10 / 5 / 1 /step]
Sets the number of consecutive paper jams required to initiate a call. This
setting is enabled only when SP5508 004 is set to 1.