System Service Mode
SM Appendix 3-37 D115/D116
Appendix:
SP Mode
Tables
5501
PM Alarm Interval CTL -
001 Printout
[ 0 to 9999 / 0 / 1 /step]
0: Alarm off
1 to 9999: Alarm goes off when the PM counter
reaches the specified value (1 to 9999) x 1000.
002 ADF
[ 0 or 1 / 1 / – ]
0: No alarm sounds
1: Alarm sounds after the number of originals passing
through the A(R)DF > 10,000
5504
Jam Alarm CTL -
001
Sets the alarm to sound for the specified jam level (document misfeeds are
not included).
[ 0 to 3 / 3 / 1 /step]
0: Zero (Off), 1: Low (2.5K jams), 2: Medium (3K jams), 3: High (6K jams)
5505*
Error Alarm
001
Sets the error alarm level.
The error alarm counter counts "1" when any SC is detected. However, the
error alarm counter decreases by "1" when any SC is not detected during
specified sheets of copies (for example, default 1500 sheets).
The error alarm occurs when the SC error alarm counter reaches "5".
[0 to 255 / 10 / 100 copies per step]
5507
Supply Alarm CTL -
001 Paper Size
0: Off, 1: On,
003 Toner
0: Off, 1: On,
005 Drum
0: Off, 1: On,
080 Toner Call Timing
0: Toner is replaced (default)
1: Toner near end or end