Bit Switches
SM Appendix 5-13 D115/D116
Appendix:
Fax Service
Program
3
Printing of the error code on
the error report
0: No 1: Yes
1: Error codes are printed on the error reports.
4
Not used
Do not change this setting.
5
Power failure report
0: Disabled 1: Enabled
1: A power failure report will be automatically
printed after the power is switched on if a fax
message disappeared from the memory when the
power was turned off last.
6
Conditions for printing the
protocol dump list
0: Print for all communications
1: Print only when there is a
communication error
This switch becomes effective only when system
switch 00 bit 6 is set to 1.
1: Set this bit to 1 when you wish to print a protocol
dump list only for communications with errors.
7
Priority given to various types
of remote terminal ID when
printing reports
0: RTI > CSI > Dial label > Tel.
Number
1: Dial label > Tel. number >
RTI > CSI
This bit determines which set of priorities the
machine uses when listing remote terminal names
on reports.
Dial Label: The name stored, by the user, for the
Quick/Speed Dial number.