OPTICS ANTI-CONDENSATION HEATER
SM 3-51 B089/B093
Installation
3.16 OPTICS ANTI-CONDENSATION HEATER
CAUTION
Unplug the machine power cord before starting the following procedure.
1. Remove the rear scale [A] ( x 3), left scale [B] ( x 2), and exposure glass
[C].
NOTE: When reinstalling the exposure glass, make sure that the mark [D] is
positioned at the rear left corner, as shown.
2. Move the 1st and 2nd scanners to the right.
3. Install the cable clamp [E].
4. Install the anti-condensation heater [F] ( x 2).
5. Join the connectors [G]
6. Attach the cable cover [H], as shown.
B089I001.WMF
B089I304.WMF
[A]
[B]
[C]
[D]
[E]
[F]
[G]
[H]