INSTALLATION PROCEDURE
SM 3 B692/B694
B692/B694
Data
Overwrite
Security Unit
1.3 INSTALLATION PROCEDURE
1. If the machine is on, switch off the main power switch.
2. Disconnect the Network cable if the NIB is installed.
3. Disconnect the Fax module cable if the fax option is installed.
4. Switch the main power switch on.
5. Check that the following “Copy SPs” are set as indicated below:
SP No. SP Name Set To:
5871 001 HDD Function Disable 1 (On)
5967 001 Document Server Set Function 1 (Off)
5846 090 USC Settings - Plain Data Forbidden 1 (Check)
5836 001 Capture Settings – Capture Function 0 (Off)
HDD Formatting (ALL)
• B089/B093 OR B135/B138
Press # to Execute
5832 001
• B147/B149
Press “Execute” key
6. Check that the following “Printer SPs” are set as indicated below:
SP No. SP Name Set To:
1006 001 Sample/Proof Print 1 (On)
7. Turn off the operation switch.
8. Turn off the main switch.
9. Disconnect the Fax cable (RJ11 connection) if installed
10. Disconnect the Network cable (RJ45 connection) if NIB is installed
11. Install either the DIMM [A] or the SD Card [B]:
• The DIMM is installed for B135/B138 or B089/B093.
• The SD Card is installed for B147/B149.
B692I902.WMF
[A]
[A]
B135/B138
[B]
B089/B093
B147/B149