SERVICE PROGRAM MODE
SM 4-27 B089/B093
Service
Tables
SP4-XXX: Scanner
Scanner Sub Scan Mag [–0.9 ~ +0.9 / 0.0 / 0.1% step]4008*
Adjusts the magnification in the sub scan direction.
Use the key to toggle between + and – before entering the value. The
specification is
±
1%. See “Replacement and Adjustment - Copy Adjustment” for
details.
Scanner Main Scan Mag [–0.9 ~ +0.9 / 0.0 / 0.1% step]4009*
Adjusts the magnification in the main scan direction for scanning.
Use the key to toggle between + and – before entering the value. The
specification is
±
1%. See “Replacement and Adjustment – Copy Adjustment” for
details.
Scanner Leading Edge Registration [–0.9 ~ +0.9 / 0.0 / 0.1 mm step]4010*
Adjusts the leading edge registration for scanning in platen mode.
(–): The image moves in the direction of the leading edge.
Use the key to toggle between + and – before entering the value. The
specification is 2
±
1.5 mm. See “Replacement and Adjustment – Copy
Adjustment” for details.
Scanner Side-to-side Registration [–4.6 ~ +4.6 / 0.0 / 0.1 mm step]4011*
Adjusts the side-to-side registration for scanning in platen mode.
(–): The image disappears at the left side.
(+): The image appears.
Use the key to toggle between + and – before entering the value. The
specification is 2
±
1.5 mm. See “Replacement and Adjustment – Copy
Adjustment” for details.
4012* Scanner Erase Margin
4012 1 Leading Edge
4012 2 Trailing Edge
4012 3 Right Side
4012 4 Left Side
Adjusts the erase margin at each side for scanning.
Do not adjust this unless the user wishes to have a scanner
margin that is greater than the printer margin.
[0 ~ 9.0 / 0.5 / 0.1 mm/step]
Scanner Free Run 4013
Performs a scanner free run with the exposure lamp on.
Press ON on the touch panel to start this feature. Press the (Clear/Stop) key to
stop.