EasyManua.ls Logo

Ricoh B089 - Toner Density Control

Ricoh B089
849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DEVELOPMENT
B089/B093 2-38 SM
2.7.6 TONER DENSITY CONTROL
Overview
There are four modes for controlling toner supply as shown in the following tables.
The mode can be changed with by SP2-921. The factory setting is sensor control 1
mode.
Basically, toner density is controlled using the standard TD sensor voltage (Vts),
toner supply reference voltage (Vref), actual TD sensor output voltage (Vt), and ID
sensor output data (Vsp/Vsg).
TD Sensor Initial
Setting (Vts)
ID Sensor Output
(Vsp/Vsg)
Vt Reference
Voltage Update
Vt Reference
Voltage (Vref)
TD Sensor Output
(Vt)
Toner Supply Clutch On Time
Calculation
New Vref
Vref Update
B027D517.WMF

Table of Contents

Related product manuals